***4/29/2022 version***

Updated all seed and workspace files to have solids working area set to "10".  This is contained in the working units under the design file settings.
This is for future compatiblity with OpenBridge Modeler files (per Bentley).

Corrected disconnected cells for the Traffic Control and Signing groups in the CADD Detailing Standards workflow.
Also removed signs (cells) that have been discontinued from our Traffic division.

Renamed custom reports under MoDOT_ORD_v10.10.01.03\Standards\Reports\MoDOT



***12/01/2022 version***

D2BS sheet updated 10/01/22

Traffic controls signs - sign numbers on the cell have been made bigger

Added Buried Fiber Optic Cable code for survey

Modified sheet seeds dgnlib's for laying out clipping shape for the Named Boundary tool (boundary chord = 1)
Added annotation for Matchline & North Arrow in Named Boundary tool in Plan sheets

Misc Bridge updates on cells

Add QuanTab variables and configuration in the workspace for consultants

Add variables in the MoDOT_ORD_v10.10.01.03.cfg file for geographic coordinate systems (commented out so consultants can define their location for the coordinate systems)



***03/15/2023 version***

D2BS sheet (excel file and dgn file) updated - effective date 4/1/23

Corrected/Modified scales on patterns

Updated/Modified symbology for existing alignment geometry

Modified sheet seeds dgnlib's in sheet model properties - toggled on "Use Annotation Scale" for references

Added POP 2024 & 2025 Sign Details (CADD_Standards\ORD Standards\Consultant Workspace\MoDOT_ORD_v10.10.01.03\Standards\Seed\Roadway\POP Sign Details)

Add QuanTab variables and configuration in the workspace for consultants

Add variables in the MoDOT_ORD_v10.10.01.03.cfg file for geographic coordinate systems (commented out so consultants can define their location for the coordinate systems)

Modified sheet models in sheets seed definition file to have Transparency "on" when cutting sheet and drawing models

Modified drawing models in "plan" sheets seed definition file to have option for syncing reference file to "Settings from Design Model" when cutting plan sheets, mainly for controlling levels

Add "Paint Overlap Detail (Rehab)" cell under MoDOT CADD Detailing Standards - Bridge - Steel Girders 



***09/06/2023 version***

Added configuration variable in the MoDOT_ORD_v10.10.01.03.cfg file for "I-70 Corridor" geographic coordinate system

Added I-70_Corridor.dty file

Removed all level overrides (color, style, weight) in the Design and Bridge border files.

Changed survey cell for unknown survey codes to "octagon with ?" instead of crosshair point

Added Resin Anchor Embedment linestyle (CADD Detailing Standard workflow - Bridge ribbon - Geometry)

Remove the wording "IF SEAL IS PRESENT ON THIS SHEET IT HAS BEEN ELECTRONICALLY SEALED AND DATED." in MoDOT Bridge Border and MoDOT Design Border files.



***10/26/2023 version***

Updated all files in workspace to ORD 10.12.02.04 version

Removed Plan Sheet Disclaimer cell

Removed duplicate words (PROJECT NO.) in MoDOT_Design_Border and MoDOT_Bridge_Border files



***03/01/2024 version***

Updated 3D drainage cells to have ability to connect to center of circular structures instead of inner wall only

Added generic nodes (2'-15') in Drainage nodes for doing drainage analysis

Removed unused 3D cells for RW labels that were used previously

Removed traffic control signs with flags in CADD Detailing Standards (not needed anymore per EPG changes)

Minor updates and fixes with feature definitions

Updated ITL for how guardrail is placed

Added updated county maps (PDF) and broke out folder directory (Current and Obsolete)

Added POP_2026.dgn for standard sign details

Added curve label for alignments that have spiral-curve-spiral curves.  The label placed at the PI of the curve.

Added XS annotation group to add utility labels on the drawing models for cross sections.

Changed "Use Slope of Surface" option to "False" for headwall feature definitions in the Drainage dgnlib.

Added TAs (Typical Applications for Traffic Control) under Standards/Seed/Roadway/TAs

Updated EAV Table (End Area Volume) to make it larger to be able to see easier when printed out.

Added "Safety Edge" label to be placed on cross sections when needed.



***10/01/2024 version***

Added USTN Capability variables

Added Laminated Neoprene Bearing Pad cell for Bridge  (MoDOT CADD Detailing Standards/Bridge/Intermediate Bents)

Renamed J1.16 MSE Wall System Data Table to J1.21 MSE Wall System Data Table for Bridge  (MoDOT CADD Detailing Standards/Bridge/Detailing Notes)

Updated settings to have Time of Concentration display in minutes instead of hours (Drainage.dgnlib)

Updated D2BS Sheet

Updated MoDOT Superelevation Rules Files.xml file

Added AutoTurn-XX and Scratch 6-10 levels

Added more TAs (Typical Applications for Traffic Control) under Standards/Seed/Roadway/TAs
	*  TA-0
	*  TA-01
	*  TA-03&5
	*  TA-03&6
	*  TA-10
	*  TA-Side_Roads

Added _D-Signing.xlsm excel file for the D-29 & D-30 sheets

Added Low_Distortion_Projection_Systems.dty file.   (This contains the coordinate systems for the I-70 and I-44 corridors and replaces the I-70_Corridor.dty file contained in previous workspace versions)
	